Medical Waste Incinerator

Basic Info.

Model NO.:30kg/hr medical incinerators
Export Markets:Global

Product Description

Technology Respond(FAQ) 

Q: What’s kind of waste can use in this equipment?  A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid waste and gas waste.  GB18484-2001. 

Q: Treatment capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion speed around 2/3 of average capacity. 

Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time daily is around 16 hours. The lifetime of incinerator between 5-10 year based on use. 

Generally, we proposition little laboratory, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people each day. Pet cremation equipment costs, little medical waste incinerator, waste incinerator manufacturers, animal incinerator china, animal waste incinerator, in case there are 200 sickbed at the hospital, that's mean you need one incinerator capacity around 400kgs each day, change to capacity per hour is around 30-40 kgs per hour. According the operation time daily, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing  A: We supply all documents and incinerators easy to installation and operation. Client can send people come to our factory to find out operation and installation. Generally, we don’t send engineer to local site if not request. The dispatch cost is additional according to order.  The second combustion chamber: 1000-1200 centi degree. 

Q: Incinerator Control Mode  A: Default Control mode is common control instance. PLC mode according to order and model. 

One person can service 02 device incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know risk of medical waste to safeguard worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

HICLOVER Top Feeding Door Waste Incinerators



HICLOVER Top Feeding Door Waste Incinerators

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke




HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 



Ability of Burner for The Incinerator of 100kg/Hr

Basic Info.

Model NO.:waste incinerators equipment manufacturers
Export Markets:Global

Product Description

Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.  * PLC Control Plane. *based on order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Application Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation 

Nanjing Clover Medical Technology Co., Ltd.. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Price of smart ash incinerator, price to buy a medical waste incinerator, cow creamator, cow cremator, creamation equipment for cats and dogs, cremating incinerator, Pyrolytic incinerator equipment technical is primary waste treatment all the world, for Medical Waste, Animal Incineration, Pet cremation and other good wste. The capacity from 10kgs/Hr. To 500kgs/Hr. Up to 6ton per day. Presently, we supply different series for local customer requirements and design upgraded incinerator with our leading technology. The updated design feature of our assortment of incinerators make them one of the most cost effective in the world.

Items Specification
YD Model YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600
Main Product List Primary Combustion Chamber
Secondary Combustion Chamber
Mix Combustion Chamber
Smoke Filter Chamber
Incinerator Common Control Case
Stainless Steel Chimney
Italy oil/gas burner: 02 units
Oil Tank (if oil fuel)

large animal incinerators

large animal incinerators

Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. Incineration is the way forward for Bio-secure waste disposal. large animal incinerators is recognized as a most efficient solution for significant risk reduction in animal waste management.

※Main Feature:
— Three Combustion Chamber
— Double Italy Burner
–Burning Rate: 12-360kgs per hour
–Combustion Chamber: 0.2M3-5.5M3
※Optional Function/Parts/Material/Burning Rate:
— Stainless Steel Chimney
— Dry Smoke Filter Chamber
— Additional Burner
— Movable Platform Feeding Door
— 3-Section Wet Scrubber System
— Chimney Height Custom Made
— Upgrade/Downgrade Burning Rate

High Temperature Incineration Procedure HICLOVER YD30



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Model YD-30 
Burning Rate  average 30 kgs/hour
Feed Capacity average 40 kgs
Paimary Combustion Chamber 200 Liters
Secondary Combustion Chamber 100 Liters
Mix Combustion Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.59Kw
Fuel Type Diesel Oil
Burner Italy Original
Oil Consumption (Diesel Oil) average 13.3 kg/hour
Gas Consumption (Natural Gas) ***
Internal Dimensions 80 x 50 x 50cm (paimary chamber)
External Dimensions 125 x 90 x 180cm (without chimney)
Temperature Monitor Yes
Oil Tank Capacity(if oil fuel) 60 Liters
Door Opening 40 x 40cm
Chimney Length 1.0 Meters
Chimney Type Stainless Steel
Equipment Gross Weight 1000 kgs



what is incineration
what is the cost of building incenerator in uganda
3d drawing of incinerator

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 



100 Kg/Hr Incinerator for Hospital Waste

Basic Info.

Model NO.:small medical waste incinerator
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber. *according to order  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimal installation on site.  * PLC Control Plane for Intelligent operation. *according to order  * New Design for pet animal cremation company.  * One year warranty on incinerator and parts in stock. 

The mill workshop local in liuhe Economic Development Zone, suburb of Nanjing and company office local in downtown area. Presently, incinerator line products market cover former Soviet Union region, Africa countries, Asia countries and Middle East region.  From year 2010, we negotiated with upgraded technology from Europe and America manufacturers and establish cooperation relationship in the territory of China market. Small incinerators, waste incinerator, animal incinerators available, clover incinerator restricted, incinerator 500kg per, incinerator china manufacturer, Unfortunately, competition in other countries market, country discrimination and worries of intellectual property rights cause failure eventually. Presently, we investment more effort, funds and technology development in our own brand, we are to be one of the largest incineration equipment on the planet. We have trading division company for skilled export business service.

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinerator: Burning Capacity 20 Kg/Hour

Basic Info.

Model NO.:incineration unit for hospital waste
Export Markets:Global

Product Description

Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimal installation on site.  *according to order  * New Design for pet animal cremation business.  * One year warranty on incinerator and parts in stock. 

Program Scope:  1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation  5.50 kg per hour waste incinerator, 50 kg/hr medical waste incinerator, 50 kg/hr rated capacity diesel incinerator,

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

pet incinerators

pet incinerators

All kindly pets owners hope their lovely dog or cat be in heaven after they leave us. We understand the special bond between pet and owner and believe that it should never be forgotten. Losing a pet can be devastating and we built our business so families can remember their pets forever. pet incinerators are cremation equipment for family dead pets, including cat, dog and small pig, etc.

Items/Model A360 A600 A900 A1200
Burning Rate *animal 20 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 60 kgs/Hr.
Feed Capacity *animal 30 kgs 50 kgs 80 kgs 100 kgs
Equipment Weight 2300 kgs 3000 kgs 4000 kgs 4300 kgs
Primary Chamber (Liters) 360 600 900 1200
Secondary Chamber (Liters) 200 200 300 500
External Dimensions (cm) 145x90x175 175 x 100 x 180 200x160x230 220x180x360
Internal Dimensions (cm) 100x60x60 130 x 70 x 65 120x90x85 130x100x90
Oil Tank(Liters) 200 200 300 300
Door Opening (cm) 48 x 60 50 x 60 62 x 80 55 x 80
Chimney (M) 5 5 5 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃