Medical Waste Management System



Items/Model

TS50(PLC)

Picture

Principle

Medical Waste Incineration 

Burn Rate

50-100 kg/hour

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Gas Flue Washing System incineration of medical waste

Feed Mode

Manual

Voltage

220V

Power

4.0 Kw

Oil Infection (kg/hour)

Typical 16.9

Gas Consumption (m3/hour)

Typical 20.2

Infection Monitor

Digital Display

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

15Meter

Chimney Sort

S.Steel

1st.

1000℃-1200℃

Residency Time

2.0 Sec.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

For additional creature incineration

Nanjing Clover Medical Technology Co.,Ltd.

ü BIO-Medical/Hospital Waste Incinerator Modular Package Form, free standing unit consisting of (Primary chamber, Secondary Chamber, stake, controller and gas flue washing machine ) how can a waste to energy plant work

ü Diesel Oil And GAS Fired Burners (Dual)

ü Stainless Steel stack for strength

ü Burning capability: 50-60kgs of waste ruined per hour. 

ü Average ash residue: 3 to 4 percent

ü Operating Temperature 850°C to maximum 1320°C or better:

ü Upto 1150°C in a secondary chamber

ü Residency Time in Secondary Chamber of two minutes

ü Thick refractory liner & insulation more than 200mm rated to 1600°C in primary chamber retains warmth, increasing efficacy

ü Separate doors for loading and ash removal

ü Loading door for maximum operator protection for immediate heat exposure

ü Burner with temperature activated modulating control

ü Dual HT Thermocouples: Allow independent control of Primary and secondary temperatures through the control panel

ü Stress mill with modulating air controller

ü Stainless Steel cladding for optimum heat retention, cool touch and hygiene controller

ü Rapid, efficient and complete medical waste disposal

ü Safe use manage

ü high-quality liner and insulatio,management of hazardous waste

ü PLC touch screen, double burner controller, preset burn times and blower

ü Temperature monitoring

ü Programmable digital temperature controls for total combustion

ü Secondary burner temperature activated controlling control

ü Fast pre-heat and persistent high temperature functionality

ü Heavy duty lock: Made by us to ensure tight locking chamber with no air openings. Simple to open and shut

ü Low energy intake rates

ü 2 efficient high efficiency burners for better fuel saving to save a hour fuel burning price.

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.


PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2021-02-23

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2021-02-23



Justice Department and EPA Reach Clean Air Settlement with Gear Box Z for Selling Defeat Devices

 

Image

After Successfully Obtaining a Preliminary Injunction, Justice Department and EPA Reach Clean Air Act Settlement with Gear Box Z for Selling Defeat Devices

August 30, 2021

Contact: Joshua Alexander, 415-972-3258, [email protected]

SAN FRANCISCO – The U.S. Environmental Protection Agency (EPA) Arizona-based Gear Box Z (GBZ) has agreed to stop manufacturing and selling aftermarket automotive products widely known as “defeat devices,” that, when installed, bypass, defeat, or render inoperative EPA-certified emission controls on motor vehicles thereby increasing emissions and harming air quality.

In January 2020, the United States sued GBZ, which manufactured and sold thousands of defeat devices, alleging that these devices violated the Clean Air Act (CAA). In March 2021, the court found that the United States would likely prevail on the merits of its case, that GBZ’s products are defeat devices, and issued a preliminary injunction ordering GBZ to immediately halt the illegal sale of the devices. In its decision, the court found that the continued selling of these defeat devices would cause irreparable harm by increasing motor vehicle emissions that impair human health and the environment.  

“This lawsuit and settlement show that the United States will not permit the manufacture and sale of illegal devices that disable emission controls and thereby harm public health and that we will vigorously enforce the CAA prohibition of such devices,” said Assistant Attorney General Todd Kim of the Justice Department’s Environment and Natural Resources Division (ENRD).

“Defeat devices in automobiles and trucks can significantly increase emissions of hazardous air pollutants,” said Acting Assistant Administrator Larry Starfield for EPA’s Office of Enforcement and Compliance Assurance. “Businesses manufacturing and selling illegal aftermarket defeat devices should take note that this is a priority enforcement focus for EPA and we will continue to actively investigate these violations of the Clean Air Act.”

“Today’s settlement will prevent the future sale of thousands of aftermarket defeat devices per year,” said Deborah Jordan, EPA’s Acting Regional Administrator for the Pacific Southwest. “As acknowledged by the court when granting the United States’ motion for a preliminary injunction, increased nitrogen oxides and particulate matter pollution stemming from defeat devices cause ‘irreparable harm’ and threaten the health of everyone, especially those with pre-existing health conditions, children, and the elderly. Although Gear Box Z’s business was small, the illegal usage of its defeat devices caused substantial excess emissions.”

The settlement prohibits GBZ from manufacturing and selling any defeat devices; it also bars GBZ and its owners from selling or transferring any intellectual property associated with these products, providing technical support for these products, and investing in or obtaining revenue from other companies’ manufacture and sales of defeat devices. Under the settlement, GBZ and its owners will pay a civil penalty of $10,000, which was based on their financial situation.

Tampering with diesel-powered vehicles by installing defeat devices can cause large amounts of nitrogen oxide (NOx) and particulate matter emissions, both of which contribute to serious public health problems. EPA expects that GBZ’s defeat devices will cause excess NOx and particulate matter emissions over the anticipated remaining life of the diesel pickup trucks equipped with them. By stopping the manufacture and sale of these products, this settlement will prevent harmful emissions from diesel trucks that, if outfitted with GBZ’s products, would pollute far more than the regulations allow. Such emissions can cause premature death, aggravation of respiratory and cardiovascular disease, aggravation of existing asthma, acute respiratory symptoms, chronic bronchitis, and decreased lung function.

Numerous studies also link diesel exhaust to increased incidence of lung cancer. Respiratory issues disproportionately affect families, especially children, living in underserved communities overburdened by pollution. Stopping the sale and use of defeat devices will help prevent harmful air pollution that exacerbates the health effects of pollutant exposures.

Stopping the manufacture, sale, and installation of defeat devices on vehicles and engines used on public roads as well as on nonroad vehicles and engines is a priority for EPA. To learn more, visit: https://www.epa.gov/enforcement/national-compliance-initiative-stopping-aftermarket-defeat-devices-vehicles-and-engines.

The consent decree for this settlement was lodged in the U.S. District Court for the District of Arizona and is subject to a 30-day public comment period and final court approval. A copy of the decree, and information on submitting comments will be available on the Department of Justice website at: www.justice.gov/enrd/consent-decrees.  

For more information on this settlement: https://www.epa.gov/enforcement/gear-box-z-inc-clean-air-act-settlement

If you suspect someone is manufacturing, selling, or installing illegal defeat devices, or is tampering with emission controls, tell the EPA by writing to tampering
@epa.gov
.

Learn more about EPA’s Pacific Southwest Region. Connect with us on Facebook and on Twitter.

EPA  @epa

Image

 

If you would rather not receive future communications from Environmental Protection Agency, let us know by clicking here.
Environmental Protection Agency, 75 Hawthorne Street, San Francisco, CA 94105 United States

Um problema inesperado de infraestrutura de ebola: resíduos

Os pacientes com esse vírus debilitante produzem 440 galões de lixo hospitalar diariamente, incluindo instrumentos, jalecos, luvas, fluidos corporais, lençóis, colchões e muito mais. É uma quantidade substancial de lixo hospitalar em qualquer situação, mas é especialmente desanimador neste caso porque precisa ser descartado com extrema cautela, para evitar o risco de propagação da infecção. O que você faz com um problema como o lixo Ebola? Porque você não quer jogá-lo no lixo.

Surpreendentemente, diz Bausch, os Estados Unidos realmente enfrentam problemas maiores quando se trata de descartar com segurança os resíduos de Ebola, que são simplesmente queimados em grandes fossas na África: “Nos Estados Unidos, é claro, estamos um tanto comprometidos com soluções de alta tecnologia , que de certa forma são um pouco mais problemáticos em termos de tratamento de todos esses resíduos, e precisamos de autoclaves ou incineradores que possam lidar com esse tipo de coisa. Não é a inativação real que é particularmente difícil; é apenas o processo de levar os resíduos da linha de frente do atendimento e da interação com os pacientes com segurança para o local onde podem ser incinerados ou autoclavados ”.

O problema nos Estados Unidos é ironicamente agravado pelo maior acesso aos cuidados médicos e pela maior qualidade dos serviços médicos disponíveis. Nos Estados Unidos, os pacientes são tratados por equipes médicas com acesso a um grande volume de suprimentos que usam para proteção, incluindo máscaras, jalecos, botas e luvas, além de desinfetantes e outras ferramentas. Além disso, os pacientes recebem extensas intervenções médicas que geram resíduos como agulhas, tubos, esparadrapo, bolsas vazias de soro e muito mais. O próprio cuidado que ajudou a maioria dos poucos pacientes de Ebola nos Estados Unidos a vencer a doença contribuiu para a enorme quantidade de resíduos gerados, destacando um buraco crítico na infraestrutura médica dos EUA – enquanto os hospitais africanos podem não ter os suprimentos e pessoal necessários para fornecer ajuda aos pacientes com ebola, eles estão pelo menos preparados para lidar com o lixo.

O CDC acaba de emitir diretrizes para ajudar os médicos e administradores a decidir sobre como lidar com os resíduos do Ebola, mas o The New York Times observa que muitas instalações não têm autoclave e incinerador, capacidade para lidar com resíduos médicos nesta escala. Alguns estados proíbem totalmente a queima de lixo hospitalar, ou barraram a incineração de lixo de Ebola, levando ao transporte de lixo através das fronteiras estaduais para instalações que podem tratá-lo, o que representa seus próprios riscos; com cada quilômetro adicionado ao transporte, há um risco maior de espalhar doenças para comunidades não expostas anteriormente.

Surpreendentemente, os defensores da queima do lixo vêm de cantos surpreendentes. Ambientalistas como Allen Hershkowitz, cientista sênior do National Resources Defense Council, apontam que: “Não há poluente que saia de um incinerador de lixo que seja mais perigoso do que o vírus Ebola. Quando você está lidando com riscos patogênicos e biológicos, às vezes a coisa mais segura a fazer é a combustão. ”

O argumento em defesa da incineração pode ser reforçado pelo fato de que as empresas de resíduos hospitalares se especializam em incineração de alta eficiência com equipamentos projetados para minimizar e reter os subprodutos da combustão, reduzindo consideravelmente a poluição geral. Os temores sobre o ebola, em vez de preocupações ambientais ou de saúde pública genuínas, estão conduzindo a decisão de pressionar contra a incineração de resíduos de ebola em muitas regiões, mas, eventualmente, os Estados Unidos terão que enfrentar os fatos: os resíduos crescentes que se acumulam nas instalações onde Pacientes com ebola recebem tratamentos que devem ser descartados com segurança e prontamente.

por: http://www.care2.com/causes/an-unexpected-ebola-infrastructure-problem-waste.html

Pet Crematorium

Basic Info.

Export Markets:Global

Additional Info.

Trademark:clover
Origin:Clover

Product Description

We want to refresh or change incinerator with new one the incinerator contain 3 units each unit 400kg/h, if u interest to make job with as pls contact me to send u drawing and details. (Baghdad ) 
Our hospitals require 3 X Medical Waste Incinerator Units (designed to 
Burn medical waste load capacity of 50kg/hr, with calorific values 
Ranging from 2, 300 kJ. Kg to 30, 000 kJ/kg at a designed thermal rate 
Of 1, 440, 000 kJ/hr. 
I was browsing through your website and noted that Model: YZ-50 or 
YD-50 might be the the desired (specified) incinerator unit. Please 
Find attached animal incinerators and other waste, animal incinerators and other waste. De, animal incinerators costs, animal incinerators manufacturers, animal incinerators price, our incinerator specifications. 
I kindly request you to send me a quotation of your Medical Waste 
Incinerator Units, detailed specs and features plus freight costs from 
Your location to Port Moresby, Papua New Guinea. 
MEDICAL WASTE INCINERATOR SPECIFICATIONS 
Capacity (4000 kg/day). 
The unit should have the following features: 
* Automatic feeding 
* Automatic ash / leftovers removal 
* Flue gas filtration system. 
* The technical & financial offer should include installation & testing and staff training. 
***The offer should be itemized. 
IMPORTANT INFORMATION: 
1. Emission standards: ( EU ) 
2. Waste type: Hazardous Medical Waste 
3. Approximate moisture content: Max. 30% 
4. Glass content: Max. 15% 
5. Building Roof Height: 8 meters 
6. Height of chimney above roof (required): At least 3 meters 
7. Fuel to be used: No. 2 ( diesel ) ( Fuel specifications attached ) 
8. Power: 380 V, 3 phase 
9. Space available inside the existing building: (Bidders should visit the building to choose the best location for installation coordinating with university engineers) 
10. Waste filled in (max. 70X120 cm ) polyethylene bags (Amman ) 
I am looking at purchasing 10-17 medical waste incinerators. Please could you give me your best price and latest catalogue for the following

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC) TS100(PLC)
Burn Rate 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour 100 kg/hour
Feed Capacity 20kg 40kg 60kg 100kg 200 kg
Control Mode PLC PLC PLC PLC PLC
Combustion Chamber 100L 210L 330L 560L 1200L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm 120x100x100cm
Secondary Chamber 50L 110L 180L 280L 600L
Smoke Filter Chamber Yes Yes Yes Yes Yes
Feed Mode Manual Manual Manual Manual Manual
Voltage 220V 220V 220V 220V 220V
Power 0.5Kw 0.5Kw 0.5Kw 0.7Kw 0.7Kw
Oil Consumption (kg/hour) 5.4–12.6 7.8–16.3 10.2–20 12.1–24 14–28
Gas Consumption (m3/hour) 6.2–11.4 8–15.7 9.8–20 9.9–26.1 10–32.2
Temperature Monitor Yes Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes Yes
Oil Tank 100L 100L 100L 100L 200L
Feed Door 30x30cm 45x40cm 55x50cm 70x55cm 80x60cm
Chimney 3Meter 3Meter 5Meter 5Meter 10Meter
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel Stainless Steel
1st. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
2nd. Chamber Temperature 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree 800degree–1000degree
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Gross Weight 1500kg 2200kg 3000kg 4500kg 6000kg
External Dimensions 140x90x120cm 160x110x130cm 175x120x140cm 230x130x155cm 260x150x180cm

Incinérateur

Informations de base.

pour Animal: Incinérateur
Forme posologique: Incinérateur
Type: Incinérateur
Fonction: Incinérateur
Marchés d’exportation: mondiaux

Information additionnelle.

Marque Déposée: CLOVER MEDICAL

Description du produit

Nanjing Clover Medical Technology Co., Ltd. est l’un des principaux fabricants d’incinérateurs de déchets en Chine. Nous sommes un fabricant local et l’un des plus grands exportateurs de Chine. L’équipement technique d’incinérateur pyrolytique est le principal traitement des déchets dans le monde entier, pour les déchets médicaux, l’incinération animale, la crémation des animaux domestiques et autres déchets solides. La capacité de 10 kg / h. Jusqu’à 500 kg / heure, jusqu’à 6 tonnes par jour. Actuellement, nous fournissons différentes séries pour les besoins des clients locaux et concevons un incinérateur mis à jour avec notre technologie de pointe. La conception mise à jour de notre gamme d’incinérateurs en fait l’un des plus rentables au monde.

Nous sommes l’un des plus grands fabricants et exportateurs d’incinérateurs de déchets de Chine. L’incinérateur pyrolytique technique est la principale méthode de traitement des déchets dans le monde entier, pour les déchets médicaux, l’incinération animale, la crémation d’animaux domestiques et autres déchets solides. Actuellement, nous fournissons des incinérateurs de petits trèfles, des incinérateurs de trèfle 500, des incinérateurs de trèfle co., Ltd., Des incinérateurs de trèfle ltd, des fabricants d’incinérateurs de trèfle en Chine, des incinérateurs de trèfle et des incinérateurs à grande échelle selon les exigences des clients locaux et nous concevons un incinérateur mis à jour avec notre technologie de pointe.
Nanjing Clover Medical Technology Co., Ltd. Tél: + 86-25-8461 0201 Fax: + 86-25-8461 0406 Ajouter: RM. 7411, No.58 Yunjin Rd., Nanjing, Chine 210019

Articles / modèle YD-10C YD-20C YD-30C YD-50C
Taux de combustion (kg / heure) 10 kg / heure 20 kg / heure 30 kg / heure 50 kg / heure
Capacité d’alimentation (kg) 40 kilogrammes 40 kilogrammes 50 kilogrammes 80 kilogrammes
Poids de l’équipement 1200 kilogrammes 1200 kilogrammes 1800 kilogrammes 2200 kilogrammes
Chambre primaire (litres) 200 200 250 400
Chambre secondaire (litres) 140 140 140 140
Dimensions extérieures (cm) 170 x 140 x 160 170 x 140 x 160 170 x 140 x 190 180 x 160 x 200
Dimensions internes (cm) 55 x 55 x 65 55 x 55 x 65 55 x 55 x 85 70 x 70 x 85
Réservoir d’huile (litres) 50 100 100 150
Ouverture de porte (cm) 38 x 48 38 x 48 38 x 48 45 × 55
Cheminée (M) 5 5 5 5
Type de cheminée Acier inoxydable Acier inoxydable Acier inoxydable Acier inoxydable
Chambre secondaire OUI OUI OUI OUI
Chambre de mélange-combustion OUI OUI OUI OUI
Chambre de filtre à fumée OUI OUI OUI OUI
Combustible de combustion Gaz de pétrole Gaz de pétrole Gaz de pétrole Gaz de pétrole
Temps de résidence 2,0 sec. 2,0 sec. 2,0 sec. 2,0 sec.
Surveillance de la température OUI OUI OUI OUI

Cementerio de animales de Australia Central

La cifra se reveló en el informe de la instalación regional de gestión de residuos de Alice Springs de octubre.

La mascota muerta que le pediste al veterinario que desechara terminará enterrada en un vertedero, en la mayoría de los lugares del país, y Alice Springs no es diferente.

“Es una combinación de caballos, perros, gatos, cerdos, cualquier animal que muere”, dijo el director de servicios técnicos del consejo de Alice Springs, Greg Buxton. “Atropellos, canguros y eso, los guardabosques los recogen y tienes que deshacerte de ellos en algún lugar higiénico. Así que los pusimos en la parte trasera del vertedero “.

La instalación está en camino de superar el total del año pasado, con 3,7 toneladas depositadas en el primer trimestre de este año financiero.

Buxton dijo que la mayoría de los consejos regionales de todo el país eliminan los animales muertos en vertederos.

“En las ciudades más grandes tienen un entorno tipo incinerador donde los incineran, mientras que nosotros no tenemos un incinerador aquí”, dijo.

por: http://www.news.com.au/national/northern-territory/central-australias-animal-graveyard/story-fnn3gfdo-1227123002725

Hazardous Waste Incinerators

Basic Info.

Model NO.:gas combustion chamber
Export Markets:Global

Product Description

Clover provide medical waste incinerators, animal and pet cremators, other solid waste incinerators to over 30 nations. We’ve re-designed the incinerators lining configuration. We also have designed and installed our very own PLC computer system into incinerator operation system. Clover know it is important that build them better, keep it simple and offer a terrific service. We create quality products that provide excellent payback on investment, our incinerators are the most powerful and thermally efficient in the industry.  The incinerator lines have small scale to large scale, up to 500kgs per hour. The combustion chamber use high strength material, biological cremation, biological incenerators compare prices, bramford rubbish incinerator, burner capacity for incinirator, buy incinerator, expensive cost but better quality than competitors. Incinerator operation system utilize PLC program control mode, give up the complex manual operation.  Key Features:  * All models with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to order  * High fever, long life of incinerator.  * Free or minimal installation on site.  * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day.  *according to order  * New Design for pet animal cremation company.  * One year warranty on incinerator and components in stock. 

Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste.  3. Community & Sea Port & Station: Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-200 YD-300 YD-500 YD-600
Burning Rate (kgs/Hour) 200 kgs/Hr. 300 kgs/Hr. 500 kgs/Hr. 600 kgs/Hr.
Feed Capacity (kgs) 400 kgs 500 kgs 800 kgs 1100 kgs
Equipment Weight 7600 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 2000 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 270 x 185 x 380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 180 x 115 x 96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 300 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Установка для сжигания отходов животных

Базовая информация.

Номер модели: двухкамерная установка для сжигания медицинских отходов
Источники очистки: переработка твердых отходов
Методы обработки: сжигание
Экспортные рынки: глобальный

описание продукта

Nanjing Clover Medical Technology Co., Ltd.

Компания Nanjing Clover Medical Technology Co., Ltd. является ведущим производителем мусоросжигательных установок в Китае. Мы – местный производитель и один из крупнейших экспортеров Китая. Установки для сжигания опасных отходов в Китае, конструкция установки для сжигания отходов в больницах, камера сжигания для сжигания, цена на установку для сжигания 10 кг / час, установка для сжигания 500 кг в час, расчет мощности печи для сжигания, Пиролитическое оборудование для сжигания отходов – это основная обработка отходов во всем мире, для медицинских отходов, кремация домашних животных и др. Твердые отходы. Емкость от 10кг / час. До 500 кг / час, до 6 тонн в день. В настоящее время мы поставляем различные серии в соответствии с требованиями местных клиентов и проектируем обновленную мусоросжигательную печь с использованием наших передовых технологий. Обновленные конструктивные особенности нашего ассортимента мусоросжигательных печей делают их одними из самых экономичных в мире.

Ключевая особенность:
* Все модели с двойной камерой сгорания. * по заказу
* Дымоход / дымоход из нержавеющей стали, долгий срок службы. * по заказу
* Высокая температура, длительный срок службы инсинератора.
* Бесплатная или минимальная установка на месте.
* Высокая скорость сжигания, от 10 кг до 500 кг в час, до 6 тонн в день.
* Плоскость управления ПЛК для интеллектуальной работы. * по заказу
* Новый дизайн для кремации домашних животных.
* Один год гарантии на инсинератор и запасные части.

Заводская мастерская расположена в зоне экономического развития Люхэ, пригород Нанкина, а бизнес-офис – в центре города. В настоящее время рынок продуктов для мусоросжигательных заводов охватывает территорию бывшего Советского Союза, страны Африки, страны Азии и Ближнего Востока.
С 2010 года мы ведем переговоры с производителями новейших технологий из Европы и Америки и устанавливаем отношения сотрудничества на территории рынка Китая. К сожалению, конкуренция на рынке других стран, дискриминация стран и опасения по поводу прав интеллектуальной собственности в конечном итоге приводят к провалу. В настоящее время мы инвестируем больше усилий, средств и развития технологий в наш собственный бренд, мы должны стать одним из крупнейших производителей мусоросжигательного оборудования в мире. У нас есть торговый филиал для профессионального обслуживания экспорта.

Предметы / Модель TS10 (ПЛК) TS20 (ПЛК) TS30 (ПЛК) TS50 (ПЛК) TS100 (ПЛК)
Скорость сжигания 10 кг / час 20 кг / час 30 кг / час 50 кг / час 100 кг / час
Емкость подачи 20кг 40кг 60кг 100кг 200 кг
Режим управления ПЛК ПЛК ПЛК ПЛК ПЛК
Камера сгорания 100л 210л 330 л 560 л 1200L
Внутренние размеры 50x50x40 см 65x65x50 см 75x75x60 см 100x80x70 см 120x100x100 см
Вторичная камера 50 л 110л 180л 280L 600 л
Камера дымового фильтра да да да да да
Режим подачи Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации Руководство по эксплуатации
Напряжение 220В 220В 220В 220В 220В
Мощность 0,5 кВт 0,5 кВт 0,5 кВт 0,7 кВт 0,7 кВт
Расход масла (кг / час) 5,4-12,6 7,8-16,3 10,2-20 12,1-24 14-28
Расход газа (м3 / час) 6,2-11,4 8-15,7 9,8-20 9,9-26,1 10-32,2
Монитор температуры да да да да да
Температурная защита да да да да да
Масляный бак 100л 100л 100л 100л 200л
Дверца подачи 30×30 см 45×40см 55×50см 70×55см 80×60 см
Камин 3 метра 3 метра 5 метров 5 метров 10 метров
Тип дымохода Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь Нержавеющая сталь
Время проживания 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек. 2.0 сек.
Вес брутто 1500 кг 2200кг 3000кг 4500кг 6000кг
Внешние размеры 140x90x120 см 160x110x130 см 175x120x140 см 230x130x155 см 260x150x180 см

Связаться сейчас Тел: + 86-25-8461 0201

Google快讯 – waste incinerator

Google
waste incinerator

每天更新 2021年8月30日
新闻

The Ministry of Environment is installing 50 incinerators to burn medical waste from Covid-19 treatment and quarantine centres in the capital and 20 …

Facebook Twitter 标记为不相关

Sonthi said contaminated waste must be burnt at the proper temperature to reduce environmental impact. While infectious waste incinerators must operate at 760C, …

Facebook Twitter 标记为不相关

AFES Waste Management Facilities plant manager Mohd Halim Ab Rahman (picture; above) said the mini incinerator in Cameron Highlands completed its …

Facebook Twitter 标记为不相关

Why waste-to-energy plants aren't the ideal solution for managing our trash. Setting up incinerator plants is “illogical” in the Indian scenario, …

Facebook Twitter 标记为不相关

These mobile charging stations follow an innovative EV 'Charging-on-Demand' … The transition from IC (internal combustion) engines to e-mobility requires …

Facebook Twitter 标记为不相关

It will be served by an energy from waste incinerator, for which Brockwell Energy has … stating non-recyclable waste should be reduced, not burned.

Facebook Twitter 标记为不相关

查看更多结果 | 修改此快讯
您收到此电子邮件是因为您订阅了Google快讯

RSS 以RSS Feed的形式接收此快讯

发送反馈

PLC Incinerator (TS50 PLC)

Basic Info.

Model NO.:TS50 PLC
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:Clover
Packing:Full Container
Standard:50 kg per hour
Origin:China
Production Capacity:1500 Units/Year

Product Description

Nanjing Clover Medical Technology Co., Ltd. Is a leading waste incinerator manufacturer in China. We are local manufacturer and one of the largest exporter of China. Pyrolytic incinerator equipment technical is main waste treatment all of the world, for Medical Waste, Animal Incineration, Pet cremation and other Solid wste. The capacity from 10kgs/Hr. To 500kgs/Hr., up to 6ton per day. Presently, we supply different series for local customer requirements and pet crematorium incinerators china price, pet crematorium manufacturers italy, pet crematorium petaling jaya, pet crematoriums, pet crematory equipment china, pet crematory equipment manufacturer, design updated incinerator with our leading technology. The updated design feature of our range of incinerators make them one of the most cost effective in the world. 
Key Features: 
* All models with Dual combustion chamber. 
* Stainless Steel chimney/stack, long lifetime. *according to order 
* High temperature, long lifetime of incinerator. 
* Free or minimum installation on site. 
* High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. 
* PLC Control Plane. *according to order 
* New Design for pet animal cremation business. 
* One year warranty on incinerator and parts in stock. 
Application Scope: 
1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 
2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 
3. Community & Sea Port & Station: Municipal Solid Waste, etc. 
4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model TS50(PLC)
Burn Rate 50 kg/hour
Feed Capacity 100kg
Control Mode PLC
Combustion Chamber 560L
Internal Dimensions 100x80x70cm
Secondary Chamber 280L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.7Kw
Oil Consumption (kg/hour) 12.1–24
Gas Consumption (m3/hour) 9.9–26.1
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 70x55cm
Chimney 5Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800–1000 degree
2nd. Chamber Temperature 1000-1200 degree
Residency Time 2.0 Sec.
Gross Weight 4500kg
External Dimensions 230x130x155cm