1. For clinic,lab, small hospital with low waste output capacity, no condition with other medical waste treatment(Underdeveloped country or area, or emergency situations ).
2. Doctor, nurse treat the syringes, needle, infusion set immediately after use, plug to play, no dispersion risk.
3. melting the syringes needle with 1250Celsius high temperature to metal slag, sterilization immediately. Destroy syringes, infusion set, can not use again.
Medical Needle Incinerator: Melt the needle waste, cut off syring tube with needle, cut off the infusion tube.
The secondary chamber must comply with the following minimum criteria:
“• Heavy steel construction
• An excess air and high temperature operational mode.
• Sufficient size and appropriate geometry to achieve a gas temperature of at least 1000 Celsius for a retention time of at least 2 seconds when pre-heated and correctly operated.
• Sufficient forced air inflow and airflow and fuel supply controls to ensure an exhaust gas oxygen content range of 6-12% at all times.
• Hot face refractory concrete-ceramic suitable for thermal shock up to 1400 Celsius and abrasion. Minimum thickness 150mm.
• Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.
• Refractory lining of all the ducts shall be done with refractory castings. Superior quality ceramic wool shall be used at all hot duct flanges and expansion joints
• An electrically powered fan forced air supply, with the capacity for variation by the operator.
• One or more fuel burners designed to use diesel fuel type 2 (vehicle standard) equipped with a spark igniter.
• A digital thermometer with connected to an electronic datalogger. The thermometer shall be located on the chamber wall away from the fuel burner.
For other animal incineration
Items/Model
TS100(PLC)
TS150(PLC)
TS300(PLC)
TS500(PLC)
Burn Speed (Typical )
100 kg/hour
150 kg/hour
300 kg/hour
500 kg/hour
Control Mode
PLC Auto.
PLC Auto.
Combustion Chamber
1200L
1500L
2000L
3000L
Internal Dimensions
120x100x100cm
150x100x100cm
170x120x100cm
210x120x120cm
Secondary Chamber
600L
750L
1000L
1500L
Smoke Filter Chamber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Feed Mode
Manual
Manual
Manual
Manual
Voltage
220V
220V
220V
220V
Power
1.38Kw
1.69Kw
2.57Kw
4.88Kw
Diesel Oil Consumption (kg/hour)
Ave.20.4
Ave.24.2
Ave.33
Ave.44
Natural Gas Consumption (m3n/hour)
Ave.24.5
Ave.29
Ave.39.6
Ave.52.8
Temperature Monitor
Yes
Yes
Yes
Yes
Temperature Protection
Yes
Yes
Yes
Yes
Oil Tank
200L
300L
500L
500L
Chimney
10Meter
10Meter
14Meter
14Meter
Chimney Type
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
1st. Chamber Temperature
800℃–1000℃
800℃–1000℃
800℃–1000℃
800℃–1000℃
2nd. Chamber Temperature
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
Residency Time
2.0 Sec.
2.0 Sec.
2.0 Sec.
2.0 Sec.
Gross Weight
6000kg
8500kg
11000kg
16000kg
External Dimensions
260x150x180cm
300x160x190cm
400x210x300cm
450x210x300cm
CE Certification Pass
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
The incinerator units shall include a temperature based electronic combustion control system that utilizes temperature and other data to inform automated or programmed cycling through the standard burn cycle: pre-heat, burn with waste addition, burn completion, cool-down. The system shall be capable of varying auxiliary fuel and air supply in both combustion chambers to achieve optimum combustion conditions. As far as practicable, the incinerator shall be of a plug and play type for ease of installation and commissioning in remote locations.
“The control system shall have a separate push button-based work station, which shall be located adjacent to the loading bay and protected from weather and impact damage. The system shall allow for rapid and straightforward intervention by the operator if the automatic system is not achieving the desired results during a burn cycle.
CE Certification Pass
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
HICLOVER now offer a full range of containerized incineration systems, placing us at the forefront of the latest transportation and industrial
trends. Containerization enables immediate waste management as the units are pre-assembled and pre-installed.
Containerization is the most feasible and viable option in contrast to the construction of on-site facilities and housing structures,
eliminating the man power and costs involved. The system has the added benefit of total mobility (both local and international), and is ideal
for military and civil camps and remote locations where infrastructure is scarce.
Incineration is the most obvious solution for total destruction of municipal waste, avoiding all the direct and indirect risks associated with
other disposal methods.
Incineration perfectly fits into a trend of treating waste in a safe way, and if possible, at the same place where it was generated to avoid
cross-contamination risk and to keep waste treatment costs at acceptable level.
All kindly pets owners hope their lovely dog or cat be in heaven after they leave us. We understand the special bond between pet and owner and believe that it should never be forgotten. Losing a pet can be devastating and we built our business so families can remember their pets forever. pet cremation equipment prices firstly according to small pet or big pet, then small incinerator for cats and small dog or big dogs. The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.
Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. Incineration is the way forward for Bio-secure waste disposal. Modern incineration is recognized as a most efficient solution for significant risk reduction in animal waste management.
The forecasted feedstock loads, and daily loading rates are generally summarized as:
• Mixed general, clinical and incinerable hazardous wastes with a wide range of calorific values and densities. The wastes will consist of 100% biomedical wastes.
• Wastes either small enough to fit within a 60 litre waste sack or broken up or shredded to less than 300mm in size.
• Operation on a daytime shift basis, 5 days per week.
TS100(PLC)
TS150(PLC)
TS300(PLC)
TS500(PLC)
Burn Rate (Typical )
100 kg/hour
150 kg/hour
300 kg/hour
500 kg/hour
Control Mode
PLC Auto.
PLC Auto.
PLC Auto.
PLC Auto.
Combustion Chamber
1200L
1500L
2000L
3000L
Internal Dimensions
120x100x100cm
150x100x100cm
170x120x100cm
210x120x120cm
Secondary Chamber
600L
750L
1000L
1500L
Smoke Filter Chamber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Feed Mode
Manual
Manual
Manual
Manual
Voltage
220V
220V
220V
220V
Power
1.38Kw
1.69Kw
2.57Kw
4.88Kw
Diesel Oil Consumption (kg/hour)
Ave.20.4
Ave.24.2
Ave.33
Ave.44
Natural Gas Consumption (m3n/hour)
Ave.24.5
Ave.29
Ave.39.6
Ave.52.8
Temperature Monitor
Yes
Yes
Yes
Yes
Temperature Protection
Yes
Yes
Yes
Yes
Oil Tank
200L
300L
500L
500L
Chimney
10Meter
10Meter
14Meter
14Meter
Chimney Type
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
1st. Chamber Temperature
800℃–1000℃
800℃–1000℃
800℃–1000℃
800℃–1000℃
2nd. Chamber Temperature
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
Residency Time
2.0 Sec.
2.0 Sec.
2.0 Sec.
2.0 Sec.
Gross Weight
6000kg
8500kg
11000kg
16000kg
External Dimensions
260x150x180cm
300x160x190cm
400x210x300cm
450x210x300cm
The proposed incinerators shall be able to be completely packed into a series of 20ft export standard sea containers.
“Warranty will be as per the UNOPS ‘contracts for the provision of goods’ under section 4.5 of the ‘general conditions of contract’ 4.5 WARRANTIES: Unless otherwise specified in the Contract, in addition to and without limiting any other warranties, remedies or rights of UNOPS stated in or arising under the Contract, the Contractor warrants and represents that:
4.5.1 The goods, including all packaging and packing thereof, conform to the specifications of the Contract, are fit for the purposes for which such goods are ordinarily used and for any purposes expressly made known in writing in the Contract, and shall be of even quality, free from faults and defects in design, material, manufacturer and workmanship;
4.5.2 If the Contractor is not the original manufacturer of the goods, the Contractor shall provide UNOPS with the benefit of all manufacturers’ warranties in addition to any other warranties required to be provided under the Contract;
4.5.3 The goods are of the quality, quantity and description required by the Contract, including when subjected to conditions prevailing in the place of final destination;
The goods are free from any right of claim by any third-party, including claims of infringement of any 4.5.4intellectual property rights, including, but not limited to, patents, copyright and trade secrets;
4.5.5 The goods are new and unused;
4.5.6 All warranties will remain fully valid following any delivery of the goods and for a period of not less than one (1) year following acceptance of the goods by UNOPS in accordance with the Contract;
4.5.7 During any period in which the Contractor’s warranties are effective, upon notice by UNOPS that the goods do not conform to the requirements of the Contract, the Contractor shall promptly and at its own expense correct such non-conformities or, in case of its inability to do so, replace the defective goods with goods of the same or better quality or, at its own cost, remove the defective goods and fully reimburse UNOPS for the purchase price paid for the defective goods; and,
4.5.8 The Contractor shall remain responsive to the needs of UNOPS for any services that may be required in connection with any of the Contractor’s warranties under the Contract.
CE Certification Pass
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
The Incinerator units shall be designed to last in operation in a tropical environment for a minimum period of 10 years if the specified maintenance schedule is followed. All metal surfaces (except combustion chamber internal fittings) shall be either galvanized, enameled, painted or otherwise treated against atmospheric and process induced corrosion,Medical waste management pdf.
The incinerator combustion chamber(s) should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion, etc.
The incinerator shell shall be made of mild steel with an adequate thickness for small units of between 3-6mm and larger units 5-10 mm depending on the construction part and painted externally with heat resistant aluminum paint suitable to withstand 250° C. The outside surface temperature of the incinerator casing should not exceed 50° C above ambient temperature and shall include a safety mesh around all hot surfaces. Cold face refractory lining of calcium silicate or superior material, minimum thickness 100 mm.
Three Combustion Chambers(Optional)
3 Ranked for high risk waste
Pet Cremation Equipment
For Pet(small/big) Cremation Business
Animal Incineration Equipment
For other animal incineration
Items/Model
TS100(PLC)
TS150(PLC)
TS300(PLC)
TS500(PLC)
Burn Rate (Average)
100 kg/hour
150 kg/hour
300 kg/hour
500 kg/hour
Control Mode
PLC Auto.
PLC Auto.
PLC Auto.
Combustion Chamber
1200L
1500L
2000L
3000L
Internal Dimensions
120x100x100cm
150x100x100cm
170x120x100cm
210x120x120cm
Secondary Chamber
600L
750L
1000L
1500L
Smoke Filter Chamber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Feed Mode
Manual
Manual
Manual
Manual
Voltage
220V
220V
220V
220V
Power
1.38Kw
1.69Kw
2.57Kw
4.88Kw
Diesel Oil Consumption (kg/hour)
Ave.20.4
Ave.24.2
Ave.33
Ave.44
Natural Gas Consumption (m3n/hour)
Ave.24.5
Ave.29
Ave.39.6
Ave.52.8
Infection Monitor
Yes
Yes
Yes
Yes
Temperature Protection
Yes
Yes
Yes
Yes
Oil Tank
200L
300L
500L
500L
Chimney
10Meter
10Meter
14Meter
14Meter
Chimney Type
Stainless Steel
Stainless Steel
Stainless Steel
Stainless Steel
1st. Chamber Temperature
800℃–1000℃
800℃–1000℃
800℃–1000℃
800℃–1000℃
2nd. Chamber Temperature
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
1000℃-1200℃
Residency Time
2.0 Sec.
2.0 Sec.
2.0 Sec.
2.0 Sec.
Gross Weight
6000kg
8500kg
11000kg
16000kg
External Dimensions
260x150x180cm
300x160x190cm
400x210x300cm
450x210x300cm
2021-02-21
450x210x300cm
All incinerators shall meet the following emission and operating standards:
• Combustion efficiency (C.E.) shall be at least 99.0%
• The combustion efficiency shall be computed as follows:
o C.E = (CO2 X 100) / (%CO2 +%CO)
Suitably designed pollution control devices such as scrubbers, filters or electrostatic precipitators, shall be installed/retrofitted with the incinerator to achieve emission limits.”
“Each unit shall include a complete vertical exhaust and stack system, including the following features:
• Steel construction.
• Refractory lining in the lower section.
• The exit height of the stack shall be not less than a range of 3-12 metres above ground level depending on the capacity of the incinerator unit.
• The diameter of the stack shall be selected by the Contractor to deliver an exhaust exit velocity of not less than 10 metres per second vertically upwards when at full scale operation.
• An emission stack sampling port shall be included immediately above the secondary chamber.
CE Certification Pass
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
• An 8 hour daily operating cycle of ash removal, pre-heat and burn with continuous loading if required. The automated burn completion and cool down cycle will take place overnight.
• The incinerators shall be capable of using diesel fuel as a supplemental fuel while the associated management equipment shall be capable of using electricity as the primary power source.
• Also consider provision for meeting international emission standards.
Able to handle an average waste production of 100kg/day
“• Minimum load capacity: 20 kg
• Maximum load capacity: 40 kg
• Nominal burning rate: 10-30 kg/hr (= 80- 240 kg range per 8hour day)
a. be based on common, well-proven and clean technology – both as a complete unit and in terms of its individual components.
b. be very robust, sturdy and capable of installation in remote locations subject to severe conditions.
d. generate residual incinerator ash conforming to <10% by volume and <25% by weight of the waste incinerated.
e. achieve a Total Organic Carbon (TOC) content in the slag and bottom ashes of less than 3%.
g. include clearly readable system operation panels.
h. include an operator’s manual (in English and French and Spanish).
i. require minimal preprocessing i.e. there shall be no/very limited need for prior sorting, crushing or shredding.
j. be capable of handling mixed solid waste streams and incinerable hazardous wastes as indicated.
k. can accommodate large variations in waste composition and calorific value.
l. allow for batch loading
m. incorporate an Air Pollution Control System suitable for basic emission control
n. have a thermal efficiency of not less than 85%.
o. primary and secondary chambers shall preferably have rounded inside corners to avoid the formation of dead zones or cold pockets
p. have very low levels of unburned material in the slag
q. include a supplement fuel source and storage unit (e.g., diesel tank),
“r. proposals shall include the fuel consumption at the rated capacity
be CE Certified, meet relevant British, EU or American Standards, or equivalent.
“
The proposed incinerator units must be complete and include all of the key features listed below and all of the associated support services and interconnections
CE Certification Pass
HICLOVER Solution for Fighting COVID-19 with CE Certification.
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)