animal incinerator

animal incinerator

animal incinerator is one type waste incinerator for animal waste and also pet cremation. the key point of animal incinerator is the feeding door size, cremation cost, what type of the feeding door and also smoke emission.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

Waste Incineration Treatment Model TS1000 1000kgs per hour Shirt Feeding



Items/Model

TS1000

Picture

 

Principle

Waste Incineration Treatment

Burn Rate

Average 1000 kg/hour

Feed Capacity

Average 3000kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

4800Liter

Internal Dimensions

400*120*100 cm

Secondary Chamber

1000Liter

Feed Mode

Manual/Forklift

Voltage

220V/380V

Electricity

5.0Kw

Oil Infection (kg/hour)

Average 67(DO)

Gas Consumption (m3/hour)

***

Temperature Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

800Liter

Feed Door

300x120cm(Electric Opening)

Chimney

6Meter

Chimney Type

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

18000kg

External Dimensions


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

700x220x320cm(without chimney)

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other animal incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

450x210x300cm

 



The cost of a small incinerator




Medical Waste Incinerator Capacity: Typical 50-100 kgs Each hour

Items/Model

TS50(PLC)

Picture

 

Principle

Medical Waste Incineration 

Burn Rate

Average 50-100 kg/hour

Feed Capacity

Average 100kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

560L

Internal Dimensions

100x80x70cm

Secondary Chamber

280L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.7Kw

Oil Infection (kg/hour)

Typical 16.9

Gas Consumption (m3/hour)

Typical 20.2

Infection Monitor

Digital Screen

Temperature Protection

Yes

Oil Tank

100L

Feed Door

70x55cm

Chimney

5Meter

Chimney Type

Stainless Steel

1st.

Gross Weight

4500kg

External Dimensions

230x130x155cm

Optional Part: Stainless Steel Wet scrubber

HICLOVER Incinerator/Parts Range


Main Feature

Medical Waste Incinerators


Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Nanjing Clover Medical Technology Co.,Ltd.

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)


TS500(PLC)

Burn Speed (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm



Sudan Kassala state and we are working on installing an incinerator for Girba hospital in Girba locality.
 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

2020-10-28

 

2020-10-28



Medical Waste Incinerator



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )


100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

 
 
********************************************************************************************************

HICLOVER Solution for Fighting COVID-19, with CE Certification Pass.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room
 

Pet Cremation Equipment


2020-10-28
 
 

Medical Environmental Waste Incinerators Auto Roll Air Filters
 
Medical Waste Incinerator |Mobile Incinerator|
Pet Animal Incinerator|Municipal Solid Waste  Incinerator

For Pet(small/big) Cremation Business

 
Online Contact Form/Subscribe to Newsletter: http://www.hiclover.com/contact/
 

Power
kW
Mcal/h 178 – 356
153 – 306
Fuel consumption rate L/h 15 – 30
Fuel Domestic fuel oil
Internal calorific value kWh/kg
Mcal 11.8
10.2 (10,200 kcal/Kg)
Density kg/dm3 0.82 C 0.85
Viscosity at 20°C mm2/s max 6
Operation Intermittent (1 min stop in 24 h)
One speed (on or off)
Sprinkler Number 1
Standard use Water, steam, diathermic oil boiler
Ambient temperature °C 0 C 40
Combustion Air Temperature °C max 60
Combustion temperature  °C 900 to 1100
Destructive capacity Kg/h (l/h) 120 (1600)
Power supply V
Hz 230 +/- 10%
50 single-phase
Electric motor rpm
W
V
A 2800
0.25
230
2.1
Motor capacitor µF/V 8/450
Ignition transformer V1 – V2
I1 – I2 230V – 8kV
1.8A – 30mA
flow 12 bans
Pump – pressure range
temperature
kg/h
bar
°C max 65
10 C 18
60
Degree of protection IP 40
Power consumption w max 0.43
Chimney height  m 6 to 8
Chimney diameter  mm Approximately 500
Tank volume  l 1000 to 1200
Number of ovens  2 to 3
Dimensions of the loading door cm About L80 x B60  
Combustion chamber: One-piece casing made of 3- and 10-mm thick sheet steel. Loading front with sealed door mounted on hinges, screw-type closing wheel, flexible seal, and refractory insulating lining.
Chamber materials made of refractory concrete with an alumina content of 42%AL2O3 and a wall thickness of 115 mm. Equipped with thermal insulation in fibrous panels made of calcium silicate with a thickness of 75 mm. It must also be equipped with a waste ignition burner.
Post-combustion chamber A post-combustion chamber for gases meeting the emission standards for certain gases (CO, HCl, SO2, NOx, etc.). 
Filter  Allowing combustion control and regulation of the treatment process;
A filter for reducing air pollution from incineration
Metal scraper  A metal scraper and an ash pan with handling handle.
Paint: light blue

Animal Incineration Equipment

 

For other creature incineration

Hospital waste Overall waste incinerator




Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

The equipment proposed Will be an incinerator specialised for Medical Wastes.  

Nanjing Clover Medical Technology Co.,Ltd.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For other creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )


100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Temperature Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-10-07

450x210x300cm




 CE Certification Pass

HICLOVER Solution for Fighting COVID-19 with CE Certification.
 
1. Medical Waste Incinerator(Containerized Mobile Incinerator|Top Loading Incinerator)
 
2. Auto Roll Air Filter for Clean Room

 

2020-10-07



An Unusual Ebola Infrastructure Problem: Waste

Patients for this debilitating virus create 440 gallons of medical waste daily, such as instruments, gowns, gloves, body fluids, linens, sheets and more. That is a considerable amount of medical waste in any circumstance, but it is particularly daunting in this situation because it ought to be disposed extremely carefully, to avoid the chance of spreading disease. What should you do with a problem such as Ebola waste? Because you don’t need to toss it in the garbage.

Somewhat astonishingly, says Bausch, the United States actually faces bigger problems in regards to safely disposing of Ebola waste, which is simply burned in large pits in Africa:”In the United States, naturally, we’re somewhat beholden to greater tech solutions, which in some ways are a tiny bit more problematic concerning treating all that waste, and we need autoclaves or incinerators that could handle that sort of thing. It’s not the actual inactivation that is particularly difficult; it is only the process of finding the waste from, of course, the frontline of care and interaction with the patients safely to the place where it could be incinerated or autoclaved.”

The difficulty in the United States is ironically compounded by the increased accessibility to medical care, and the high quality of healthcare services, available. In the United States, patients have been treated with medical teams with access to a massive volume of supplies they use for protection, such as masks, gowns, booties, and gloves, together with sanitizers and other tools. Moreover, patients receive extensive medical interventions which create waste such as needles, tubing, medical tape, empty IV bags, and more. The very care which has helped the majority of the handful of Ebola patients in the United States conquer the disorder has contributed to the huge amount of waste created, highlighting a critical hole in U.S. medical infrastructure — while African American hospitals may have lacked the supplies and personnel required to provide aid to Ebola patients, they are at least prepared to handle the waste.

The CDC only issued guidelines to assist clinicians and administrators decide upon how to handle Ebola waste, but The New York Times notes that many facilities do not have the autoclave, and incinerator, ability to take care of medical waste with this scale. Some countries prohibit the burning of medical waste altogether, or have barred incineration of Ebola waste, resulting in the transport of waste across state boundaries to facilities which could handle it, which introduces its own risks; with each mile added to transportation, there is a greater risk of spreading disease to previously unexposed communities.

Astonishingly, defenders of burning the garbage come from surprising corners. Environmentals such as Allen Hershkowitz, National Resources Defense Council senior scientist, point out :”There is no pollutant that is going to come out of a waste incinerator that is more dangerous than the Ebola virus. When you are dealing with pathogenic and biological hazards, occasionally the safest thing to do is combustion.” Fears about Ebola, rather than genuine ecological or public health issues, are forcing the decision to push against incineration of ebola waste in several regions, but eventually, the United States is going to need to face facts: The mounting waste which accumulates in facilities where Ebola patients receive treatments needs to be disposed of safely, as well as instantly.

The argument in defense of incineration can be bolstered by the fact that medical waste companies specialize in high-efficiency incineration with equipment designed to minimize and trap byproducts of combustion, reducing overall pollution considerably. Fears about Ebola, rather than genuine environmental or public health concerns, are driving the decision to push against incineration of ebola waste in many regions, but eventually, the United States is going to have to face facts: The mounting waste that accumulates in facilities where Ebola patients receive treatments needs to be disposed of safely, and promptly.

 

by: http://www.care2.com/causes/an-unexpected-ebola-infrastructure-problem-waste.html

HICLOVER TS Model Incinerator



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER Incinerator/Parts Range

Main Feature

Medical Waste Incinerators

HICLOVER 10-500kgs/Hr.Double Combustion Chambers

Single Combustion Chamber

Small, Cheap,10-20kgs/Hr.

Three Combustion Chambers(Optional)

3 Ranked for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For additional creature incineration


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Typical )

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Power

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm




UNAMID  supports  its  dependants  via  the  operation  of  several  self-sustained  camps located  across the  mission  AOR.   These camps contain  all elements representative of small communities.  These communities include hospitals and medical  facilities, power generation  stations, grocery shops, kitchen  and dining facilities and large scale use of packaged   material in plastic,  cardboard and similar. The waste generated  in  these camps  are  therefore   representative   of  average   small   communities without   heavy industry.   The  main objective of this document  is  to  provide potential bidders  with necessary   information   to   supply   the   large   capacity   containerized   incinerators   to UNA M I D as described  in subsequent clauses.
1. Medical waste incinerator – Small
2. Medical waste incinerator – Medium
3. General waste incinerator – Small
4. General waste incinerator – Medium
5. General waste incinerator – Large
5. General waste incinerator – Large with automated feeding system
Supply of Medical and General waste incinerators
FOR THE PROVISION OF
LARGE CAPACITY CONTAINERIZED INCINERATOR AND ACCESSORIES

The proposed   incinerators shall  be  built  into standard  20ft  lSO contai ners or alternatively built into similar footprint complete with  ISO load  handling facil ities (hooks噜  eyelets, etc). The number of conta iners/container sized  modules required  for each  unit is at the discretion of the Contractor.
•Thermocouple
•temperature gauge
•fire rope 
•burn er  
•induction air fan
•digital temperature display panel
The incinerator combustion chamber(s) should be designed for easy maintenance of all internal parts including the refractory and insulation. Materials used in the individual parts of the incinerator shall be heat resistance and also be protected against oxidation, corrosion , etc. The incinerator shell shall be made of mild steel with an adequate thickness (minimum 15 mm) and painted externally with heat resistant aluminium paint suitable to withstand 250 °C. The outside surface temperature of the incinerator casing should not exceed 50 °C above ambient temperature and shall include a safety mesh around all hot surfaces. Cold face refractory lining of calcium silicate or superior material, minimum thickness 100mm.
•Heavy steel construction.
•Fixed hearth geometry and starved air gasification operationa l mode.
•Hot face refractory concrete-ceramic suitable for thermal shock up to  1400 Celsius and abrasion. Minimum thickness  150mm.
•Cold face refractory lining of calciu m si l icate or superior material, minimum thickness 100mm.
•Refractory  lining of all the ducts shall be done with refractory castings. Su perior quality ceramic wool shall be used at all hot duct flanges and expansion j oints.
•Multi ple electric ignition fuel bu rners designed to use automotive d iesel fuel.
•Flame of the primary burner shall be oriented towards the center of the uni t which does not impinge directly on the refractory floor or wall. The secondary burner shall be positioned in such a way that the flue gas passes through the flame.
•The unit shal l prevent leakage of the hot flue gas and any backfire.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-17



how so i buy an incineration

you have to do custom clearance your side. and shipping document with bill of lading, invoice, packing list only. we have incinerator in PK and AFG but iam not sure where it is. all incinerator passed EU CE and ISO. if natural gas or LPG fuel, you have to contact with local gas supplier to know price, we only supply gas burner. if oil fuel, we supply oil system and oil tank already. installation, we assembly all we can do before leave and local working almost on chimney, control case, oil system as our indication guider on the machine. local site have to build a incineration operation house, simple type with concrete foundation.
by now, covid19, we support online or video guide and free cost.
medical waste trucks
waste incinerator tanzania
modern incineration technology
ready mace incinerator
the need for a hospital incinerator
incinerator for hazardous waste construction
manufacturers of fuel disposal in chaina

Small scale incinerator for hospital 5kgs 10kgs 20kgs and 30kgs per hour average

50 bed hospital proposal model TS5 or TS10 incinerator
200 bed hospital proposal model TS50 incinerator
we have more than 1000kgs per hour capacity incinerator.
How does a hospital incinerator work?
The incinerator comprises primary and secondary combustion chambers. The burning zone 
of the primary chamber is accessible through a door at the front which lets in air and allows the operator to light the fire and remove the ash. The medical waste is dropped in through a loading door above the primary chamber.
How is hospital waste disposed of?
Two common methods of disposing of hospital-generated medical waste include incineration 
or autoclaving. Incineration is a process that burns medical waste in a controlled environment. … 
State regulations may mandate off-site incineration for certain types of waste.
The main purpose of any medical waste incinerator is to eliminate pathogens from waste and 
reduce the waste to ashes. However, certain types of medical wastes, such as pharmaceutical 
or chemical wastes, require higher temperatures for complete destruction.