animal incinerators

animal incinerators

Animal diseases, new virus strains and spread of infectious diseases are only few of the consequences of improper animal waste treatment. animal incinerators is the way forward for Bio-secure waste disposal. Modern incineration is recognized as a most efficient solution for significant risk reduction in animal waste management.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

HICLOVER 10-500kgs/Hr.Double Combustion Chambers



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.
HICLOVER, Nanjing Clover Medical Technology Co.,Ltd, supply system solutions for medical environmental protection, animal and pet cremation engineering, other municipal solid waste incineration project.

Three Combustion Chambers(Optional)

3 Chambers for high risk waste

Pet Cremation Equipment

For Pet(small/big) Cremation Business

Animal Incineration Equipment

For additional creature incineration

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Typical )


100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-09-17

300x160x190cm

400x210x300cm

450x210x300cm


TECH SPECS FOR 200KGHOUR INCINERATOR 

The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg 
The Temperatures of combustion: Minimum will be 850oC and max 1400oC
Post combustion: >1100oC.
The Internal diameter of the Chimney: Ø 400mm² and its height: 8 m 
The Volume of the combustion chamber: 1.200 L 
The Dimension of the door for loading in cm: 70×70. 
* Burner with fuel, mono-bloc casting guiding type with horizontal flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve. 
* A secondary injection of air to ensure perfect oxygen content. 
A control box ensuring the complete cycle of combustion. 

Fan: 
* Electro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and following the control of the automatic cycle. 
Controls and regulations: 
Control box water tight to dust, including: 

* A switch circuit breaker for each engine (ventilators and burners). 
* A timer with adjustable temporization for the regulation of each burner. 
* A regulator with digital watching for the temperature of combustion. 
* A regulator with digital watching for the temperature of post combustion. 
* Electric box.

The de- ashing must be done in the bottom of the combustion chamber or the deashing should be Automatic or manual batch de ashing. 
Process Filtering system: Scruber to be mentioned as optional
Emission Standards Compliance: BS 3316 or equivalent standard
Capacity to treat Plastic: Not less than 40% by weight
The supplier must give batches of spare parts of first urgency and consumable of the incinerator.
The installed incinerator must bear a one year guarantee.
The supplier shall perform an onsite installation of the incinerator.
The technical training of operators will have to be provided and given by a technician from  
the factory; it will consist of curative and preventive maintenance, and the use of machine, etc 
Fence Wire for Incinerator House (Chain Link) should be NOT less than 2.5Meters height.
Waste Storage Bay and Ash Pit drawings attached.
 
This material and equipment must include in the shed of the incinerator: foundation in rubble stone, isolation roofing against humidity; elevation with brick of 20 cm (bloc cement), continuing lintel (linteau) in reinforced concrete; steel frame (charpenteen metal); 


HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-17



High Temperature Protection Gloves and High Temperature Protection Masks for incinerator operation

High Temperature Protection Gloves and 
High Temperature Protection Masks for incinerator operation
_Foxmail.1@f26008f6-fb66-730f-d093-c803c89a82ce” border=”0″ width=”309.5″ height=”282.5″>_Foxmail.1@0c67d671-7535-fc66-0750-f7cf6ebb8e72” border=”0″ style=”font-family: 微软雅黑; background-color: transparent;” width=”375″ height=”403.5″>

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
how to incinerate aerosol spray
incinerator for sanitary napkins for schools
dial thermometer for incinerators
mobile incinerator medical waste
what are the costs and benefits of building a brick incinerator for hospital
drum inceniration

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber
Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes

Advantages of incineration

Advantages of Waste Incineration

    Decreases Quantity of Waste. …
    Efficient Waste Management. …
    Production of Heat and Power. …
    Reduction of Pollution. …
    Incinerators Have Filters For Trapping Pollutants. …
    Saves on Transportation of Waste. …
    Provides Better Control Over Odor and Noise. …
    Prevents the Production of Methane Gas.

Incinerator Items/Model TS20(PLC) TS30(PLC)
Burn Rate (Average) 20-30 kg/hour 30-50 kg/hour
Feed Capacity(Average) 40kg/feeding 60kg/feeding
Control Mode PLC Automatic PLC Automatic
1st. Chamber Composition Hot Face Thickness: ≥115 mm Thickness: ≥115 mm
55% of Al203 55% of Al203
1750°C Grade 1750°C Grade
2nd. Chamber Composition Hot Face Thickness: ≥200 mm Thickness: ≥200 mm
75% of Al203 75% of Al203
1790°C Grade 1790°C Grade
Chamber Cold Face Material High Rate Refractory Ceramic Fiber High Rate Refractory Ceramic Fiber
Other Parts Hot Face Refractory Heavy Duty with steel fiber Heavy Duty with steel fiber
Burner operation Automatic On/Off Automatic On/Off
Dry Scrubber Including Including
Wet Scrubber Optional Optional
Top Loading Door Optional Optional
Paint for outside face 250°C Grade 250°C Grade
Sealing Material Refractory Ceramic Fiber Refractory Ceramic Fiber
Upgrade Containerized Mobile Type Optional Optional
CE Certificate CE(2006/42/EC,2014/30/EU CE(2006/42/EC,2014/30/EU
ISO Certificate  ISO9001:2015  ISO9001:2015
High-tech Enterprise Certificate  Yes Yes


What is the importance of incineration?
Incineration is widely used to reduce the volume of municipal solid waste, to 
reduce the potential infectious properties and volume of medical waste, and to 
reduce the potential toxicity and volume of hazardous chemical and biological waste.

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
plastic incineration process
nanjing clover medical technology co ltd
electic diesel incinerator
which chinese company’s are into waste management systems
how incinerators work
recycling rubbish plant

Items/Model TS10(PLC) TS20(PLC) TS30(PLC) TS50(PLC)
Burn Rate (Average) 10 kg/hour 20 kg/hour 30 kg/hour 50 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 100L 210L 330L 560L
Internal Dimensions 50x50x40cm 65x65x50cm 75x75x60cm 100x80x70cm
Secondary Chamber 50L 110L 180L 280L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 0.75Kw 0.83Kw 0.99Kw 1.2Kw
Diesel Oil Consumption (kg/hour) Ave.8.4 Ave.10.9 Ave.13.3 Ave.16.9
Natural Gas Consumption (m3n/hour) Ave.10.1 Ave.13 Ave.16 Ave.20.2
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
Items/Model TS100(PLC) TS150(PLC) TS300(PLC) TS500(PLC)
Burn Rate (Average) 100 kg/hour 150 kg/hour 300 kg/hour 500 kg/hour
Control Mode PLC Auto. PLC Auto. PLC Auto. PLC Auto.
Combustion Chamber 1200L 1500L 2000L 3000L
Internal Dimensions 120x100x100cm 150x100x100cm 170x120x100cm 210x120x120cm
Secondary Chamber 600L 750L 1000L 1500L
Smoke Filter Chamber Dry Scrubber Dry Scrubber Dry Scrubber Dry Scrubber
Feed Mode Manual Manual Manual Manual
Voltage 220V 220V 220V 220V
Power 1.38Kw 1.69Kw 2.57Kw 4.88Kw
Diesel Oil Consumption (kg/hour) Ave.20.4 Ave.24.2 Ave.33 Ave.44
Natural Gas Consumption (m3n/hour) Ave.24.5 Ave.29 Ave.39.6 Ave.52.8
Temperature Monitor Yes Yes Yes Yes
Temperature Protection Yes Yes Yes Yes
The control system shall include an electronic performance monitoring and logging 
system. The system shall be capable of monitoring and logging chamber temperatures 
at regular intervals (not less than once per minute, with the capacity to vary the logging 
frequency). The system shall include the capacity to download the performance data by 
USB connection.
All the measuring devices attached with the incinerator should have digital display 
and should have provision of connecting to the recording system, which should include
fuel meter and separate energy meter.
The temperature shall be determined against the inside wall of the combustion 
chambers. An audible and visible alarm shall be installed to warn the operator when 
the secondary temperature drops to below the required temperature.
The primary chamber must meet or exceed the following criteria:
“• Heavy steel construction.
 thermocouple
• temperature gauge
• fire rope
• burner
• induction air fan
• digital temperature display panel”
Optional maintenance service The contractor shall deploy an expert, fully equipped 
with all required tools and equipment, to the client to provide maintenance service of the
 installed waste incinerators, including all the parts and components (e.g., burners, 
ignitors, temperature gauges) when required.  
4.5.1 The goods, including all packaging and packing thereof, conform to the 
specifications of the Contract, are fit for the purposes for which such goods are 
ordinarily used and for any purposes expressly made known in writing in the Contract, 
and shall be of even quality, free from faults and defects in design, material, 
manufacturer and workmanship;
4.5.2 If the Contractor is not the original manufacturer of the goods, the 
Contractor shall provide UNOPS with the benefit of all manufacturers’ 
warranties in addition to any other warranties required to be provided under the Contract;
4.5.3 The goods are of the quality, quantity and description required by the 
Contract, including when subjected to conditions prevailing in the place of final destination;
The goods are free from any right of claim by any third-party, including claims 
of infringement of any 4.5.4intellectual property rights, including, but not limited 
to, patents, copyright and trade secrets;
4.5.5 The goods are new and unused;
4.5.6 All warranties will remain fully valid following any delivery of the goods 
and for a period of not less than one (1) year following acceptance of the goods 
by UNOPS in accordance with the Contract;
4.5.7 During any period in which the Contractor’s warranties are effective, 
upon notice by UNOPS that the goods do not conform to the requirements 
of the Contract, the Contractor shall promptly and at its own expense correct 
such non-conformities or, in case of its inability to do so, replace the defective 
goods with goods of the same or better quality or, at its own cost, remove the
 defective goods and fully reimburse UNOPS for the purchase price paid for 
the defective goods; and,
4.5.8 The Contractor shall remain responsive to the needs of UNOPS for any 
services that may be required in connection with any of the Contractor’s 
warranties under the Contract.

Medical Waste Incinerator: Essential Medical Waste Disposal Services Provided By Meda Send

Hazardous wastes are those chemicals and medications that are toxic and infectious which can effectively affect the wellness of the people upon exposed. These may also be laboratory medicines that are used by physicians in aid for harsh and severe diseases and disorders of individuals. Disposing these hazardous waste wouldn’t be a difficult job because Meda Send will become your aid in this matter. They will present medical facilities containers in colored red covered by red plastic where they can put their toxic wastes. They’re also giving medical facilities sufficient time in collecting all of the hazardous wastes which may be discovered in their own place. This is essential before permitting the pickup truck of this company to get your collected hazardous wastes.

They are extremely much concern about the health of the people inside and outside of the healthcare facility hence they wanted to ensure that they wouldn’t be exposed and become levied together with the toxins and other dangerous chemicals coming from this hazardous waste. Considering that Meda Send is always accessible, medical facilities would always have an assurance of a quick disposal of waste particularly when there are already huge quantity of toxic waste in their own place. Medasend.com Posts

Meda Send is very committed and devoted in giving waste solutions to all the people. They could effectively handle medical disposal needs of health facilities using their pace in addition to accuracy. They’re extremely effective in providing the people waste management solutions that aims for a healthy environment not just covered by the men and women that are inside the medical facility but also with all the men and women locally. With the support of medical waste disposal services of the business, people are guided with the correct waste management they have to do. This isn’t simply great for nurses and physicians but also for all the people as well.

They’re given greater opportunity to become well-equipped with the correct segregation of waste. This is very important to eliminate danger since these wastes are regarded as detrimental to people and to the surroundings. They’re taught on the ideal location where to put their waste. This can be through allowing them to segregate their waste in a red plastic. They’re also accessible 24/7 hence they make sure that waste compliance needs of the folks are given high importance that the provider isn’t taking for granted.

Thus, for medical facilities which are rendering services to large or small group of people, Meda Send could be among the greatest companies that could give you safe and healthy environment that could cater the needs of the people towards a healthy and safe community to live. One of the most dangerous kinds of waste that people will need to get rid of is toxic wastes. These are the sort of wastes which completely pose possible or substantial risks to people particularly to general health and to the environment. These wastes are also called special wastes because they can’t be immediately disposed compared to other kinds of wastes.

Therefore, in order to relieve all of the worries of the people regarding this matter Meda Send provides hazardous waste disposal which could help medical facilities. They’re supplying cost-effective in addition to secure services that could easily and effective disposed your toxic waste. They’re extremely consistent in giving safe in addition to environmental-friendly solutions to the men and women in order to disposed common present toxic waste in medical facilities. They’re the best business that will give your medical facility toxic waste disposal program which will be successful towards your goal for a healthy and secure environment for those people. Don’t miss the opportunity to avail any of the services provided by Meda Send for a healthful and secure environment. This would always ensure that you will have a healthy environment that’s free elements that pose health dangers.

Most men and women are aware that there is a large number of medical wastes which are being produced by the majority of the medical facilities like hospitals, clinics and many other health facilities each day. Even though some healthcare facilities are regarded as knowledgeable and proficient in simplifying their wastesthey still will need to seek a company that can guide them and assist them on how they’re likely to dispose their waste correctly particularly when cases that they can no longer handle appropriate medical waste in their own place.

That is why Meda Send would be an effective response to what medical facilities are greatly in need of in terms of their wastes and trash each day. They’re among those very recognized companies all around the world that’s quite specialized in regards to healthcare and appropriate medical waste disposal. They’re not just aiming to assist people in managing their waste sine they also plan to provide a healthy community free from diseases and disorders which could possibly be due to improper disposal of waste.

They are given greater chance to be well-equipped with the proper segregation of waste. This is very important to get rid of risk since these wastes are considered to be harmful to people and to the environment. They are taught on the right place where to put their waste. This is through allowing them to segregate their waste in a red plastic. Medical waste disposal of the company is known to be very effective and efficient since they are providing consistent type of truck pickup grid making the people feel at ease in scheduling medical waste pickups. They are also available 24/7 hence they make sure that waste compliance needs of the people are given high importance that the company is not taking for granted.

So, for medical facilities that are rendering services to large or small group of people, Meda Send could be one of the best companies that could give you safe and healthy environment that could cater the needs of the people towards a healthy and safe community to live.

by: http://ourbdspace.com/blog/34552/medical-waste-incinerator-essential-medical-waste-disposal-services-provide/

Best Feeding Door HICLOVER 10-500kgs/Hr.Double Combustion Chambers Waste Incinerators



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

HICLOVER is currently offering a broad selection of medical waste incinerators, designed to provide efficient waste destruction, using best available technologies and environmentally friendly procedure. Due to the secondary room with its 2 minute retention period, our healthcare incinerator range is well suited to process clinical waste.

 

Our products guarantee effective, clean and hassle-free disposal of medical waste is possible. The incineration of clinical waste such as pathological waste (red bag waste), Biohazards & Sharps, General Medical Waste, from Hospitals, Research Center, Pharmaceutical Companies, Medication Manufactures, Primary Care Trusts, Cosmetic Surgery Clinics, Nursing Homes, Care Homes and other Clinical Waste.


Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Rate (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

PLC Auto.

PLC Auto.

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

200L

300L

500L

500L

Feed Door

80x60cm

80x60cm

 

 

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Form

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm


Type of waste: medical and industrial (solid and semi solid hazardous)
Type of waste : Bio-medical & Hazardous (Solid and Semi Solid) 
If you are a hospital then Please also tell how many bedded hospital : No aren’t a hospital 
Quantity of waste generated per day in kg : 6000 kg
Duration C incinerator will be used per day :1 C 16 hours 
Approximate moisture content: 47 to 53%
Availability of power and type : 3 Phase, 440 Volts
Details of space available : Min. 10000 Sq.  ft.
Do you require an automatic loading system? Depends if it is a continuous burning or interval burning.
How soon do you require the system to be delivered? 8 weeks
Whether the location is a coastal area : No
An other specific requirements: Automatic PLC Control System.
Burning Rate: 500kg/hour
Volumetric capacity Primary Chamber: 500kg
Burner Type: Diesel Operated
Burning Process: Continuous

HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

 

2020-09-16



General waste incinerator, dual chamber (primary & secondary)



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Items/Model

TS30(PLC)

Picture

 

Burn Speed

Typical 30-50 kg/hour

Feed Capacity

Typical 60kg/feeding

Control Mode

PLC(Programmable Logic Controller Incinerator)

Combustion Chamber

330L

Internal Dimensions

75x75x60cm

Secondary Chamber

180L

Smoke Filter Chamber

Yes

Feed Mode

Manual Feeding

Voltage

220V

Electricity

1.0 Kw

Oil Consumption (kg/hour)

Typical 13.3

Gas Consumption (N.G, m3n/Hour)

***

Gas Consumption (L.P.G, m3n/Hour)

***

Temperature Monitor

Four Digital Display

Temperature Protection

Yes

Oil Tank

600L 

Feed Door

55x50cm

Chimney

5Meter 

Chimney Sort

Stainless Steel

1st.

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

3000kg

External Dimensions




General waste incinerator, dual chamber (primary & secondary), average waste production 200kg/day, nominal burning rate 25 kg/hr (200 kg per 8 hours per day). 380/400 Vac ±10%, 50Hz ±3%, 3Ph or 220/240Vac ±10%, 50Hz ±3%, 1Ph. Diesel fuel storage capacity of the unit for 5 working days in 8 hours each. Minimum life expectancy of 10 years. Meet EU CEC 2000, US AP42, EPA 1995 standards of emissions and operations or equivalent.General waste incinerator, dual chamber (primary & secondary), average waste production 125kg/day, nominal burning rate 15.63 kg/hr (125 kg per 8 hours per day). 380/400 Vac ±10%, 50Hz ±3%, 3Ph or 220/240Vac ±10%, 50Hz ±3%, 1Ph. Diesel fuel storage capacity of the unit for 5 working days in 8 hours each. Minimum life expectancy of 10 years. Meet EU CEC 2000, US AP42, EPA 1995 standards of emissions and operations or equivalent.General waste incinerator, dual chamber (primary & secondary), average waste production 75kg/day, nominal burning rate 9.4 kg/hr (75 kg per 8 hours per day). 380/400 Vac ±10%, 50Hz ±3%, 3Ph or 220/240Vac ±10%, 50Hz ±3%, 1Ph. Diesel fuel storage capacity of the unit for 5 working days in 8 hours each. Minimum life expectancy of 10 years. Meet EU CEC 2000, US AP42, EPA 1995 standards of emissions and operations or equivalent.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

175x120x140cm

 



Incinerator Model TS10



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Incinerator Model TS10 PLC, Overview

 


This model Building is dual/double combustion Room with 02 Components oil burner, batch load incineration Gear. 

Items/Model

TS10(PLC)

 

 

 

Picture

 

Burn Rate

Average 10 kg/hour

Feed Capacity

Average 20kg/feeding

Control Mode

Programmable Logic Controller(PLC) Panel

Combustion Chamber

100L

Internal Dimensions

50x50x40cm

Secondary Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

typical 8.4kg/hour

Gas Consumption (m3/hour)

typical 10.1m3/hour

Temperature Monitor

Yes

Temperature Protection

Yes

Oil Tank

100L

Feed Door

30x30cm

Chimney

5 Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

1500kg

External Dimensions

140x90x120cm


Combustion Chamber Volume (m3) 1.25m3
Gas Retention 2-3 Seconds
Operational Temperature Minimum 850°C for the primary chamber; min 1100
oC for the secondary chamber.
Metal Thickness 4mm
Average Ash Residue (%) 3%
Dimensions (l, w, h) 1.85m x 1.11m x 8.10m
Shipping Weight (kg) Up to 6 tonnes- anything less not acceptable
Fuel Consumption 13 – 18 liters per hour
Burn Rate* up to 100kg per hour
Thermostatic Device Included
Door Size (m) 0.64m x 0.54m minimum for ease of loading
Stack The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings within 50 meters radius should be taken into account. Point for the measurement of emissions shall be provided.
The addition of dilution air after combustion in order to achieve the requirement of these guidelines is unacceptable.
Diesel Tank A reinforced steel tank with a capacity of min 500 litres. The diesel tank shall come complete with a stand and connection valves.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator