Incinerator Model TS10



Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.


Incinerator Model TS10 PLC, Overview

 


This model Building is dual/double combustion Room with 02 Components oil burner, batch load incineration Gear. 

Items/Model

TS10(PLC)

 

 

 

Picture

 

Burn Rate

Average 10 kg/hour

Feed Capacity

Average 20kg/feeding

Control Mode

Programmable Logic Controller(PLC) Panel

Combustion Chamber

100L

Internal Dimensions

50x50x40cm

Secondary Chamber

50L

Smoke Filter Chamber

Yes

Feed Mode

Manual

Voltage

220V

Power

0.5Kw

Oil Consumption (kg/hour)

typical 8.4kg/hour

Gas Consumption (m3/hour)

typical 10.1m3/hour

Temperature Monitor

Yes

Temperature Protection

Yes

Oil Tank

100L

Feed Door

30x30cm

Chimney

5 Meter

Chimney Type

Stainless Steel

1st. Chamber Temperature

1000℃-1200℃

Residency Time

2.0 Sec.

Gross Weight

1500kg

External Dimensions

140x90x120cm


Combustion Chamber Volume (m3) 1.25m3
Gas Retention 2-3 Seconds
Operational Temperature Minimum 850°C for the primary chamber; min 1100
oC for the secondary chamber.
Metal Thickness 4mm
Average Ash Residue (%) 3%
Dimensions (l, w, h) 1.85m x 1.11m x 8.10m
Shipping Weight (kg) Up to 6 tonnes- anything less not acceptable
Fuel Consumption 13 – 18 liters per hour
Burn Rate* up to 100kg per hour
Thermostatic Device Included
Door Size (m) 0.64m x 0.54m minimum for ease of loading
Stack The chimney should have a minimum height of 10 meters above ground level and clear the highest point of the building by not less than 3 meters for all roofs. The topography and height of adjacent buildings within 50 meters radius should be taken into account. Point for the measurement of emissions shall be provided.
The addition of dilution air after combustion in order to achieve the requirement of these guidelines is unacceptable.
Diesel Tank A reinforced steel tank with a capacity of min 500 litres. The diesel tank shall come complete with a stand and connection valves.
HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

2020-09-16

 

2020-09-16



animal incinerator prices

animal incinerator prices

animal incinerator prices according to the capacity or the size want to cremation. The pet cremation equipment humanized design with movable platform, small space covers for modern pet cremation business owner all over the world.

Items/Model A1500 A2400 A4000 A5500
Burning Rate *animal 90 kgs/Hr. 150 kgs/Hr. 200 kgs/Hr. 400 kgs/Hr.
Feed Capacity *animal 120 kgs 200 kgs 300 kgs 500 kgs
Equipment Weight 7000 kgs 8300 kgs 13000 kgs 16500 kgs
Primary Chamber (Liters) 1500 2400 4000 5500
Secondary Chamber (Liters) 500 1200 1500 1500
External Dimensions (cm) 240x170x380 260x220x420 320x220x460 360 x 220 x 475
Internal Dimensions (cm) 150x100x96 220x110x100 257x147x108 300 x 147 x 125
Oil Tank(Liters) 500 500 500 500
Door Opening (cm) 59 x 81 90 x 110 108 x 128 108 x 128
Chimney (M) 10 10 14 14
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES
1st. Chmaber Temperature 800℃–1000℃ 800℃–1000℃ 800℃–1000℃ 800℃–1000℃
2nd. Chmaber Temperature 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃ 1000℃-1200℃

HICLOVER Top Openning Door Waste Incinerators



Top Openning Door Waste Incinerators

Items/Model

TS100(PLC)

TS150(PLC)

TS300(PLC)

TS500(PLC)

Burn Speed (Average)

100 kg/hour

150 kg/hour

300 kg/hour

500 kg/hour

Control Mode

PLC Auto.

Chimney

10Meter

10Meter

14Meter

14Meter

Chimney Type

Stainless Steel

Stainless Steel

Stainless Steel

Stainless Steel

1st. Chamber Temperature

800℃–1000℃

800℃–1000℃

800℃–1000℃

800℃–1000℃

2nd. Chamber Temperature

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

1000℃-1200℃

Residency Time

2.0 Sec.

2.0 Sec.

2.0 Sec.

2.0 Sec.

Gross Weight

6000kg

8500kg

11000kg

16000kg

External Dimensions

260x150x180cm

300x160x190cm

400x210x300cm

450x210x300cm

2020-09-02

PLC Auto.

Combustion Chamber

1200L

1500L

2000L

3000L

Internal Dimensions

120x100x100cm

150x100x100cm

170x120x100cm

210x120x120cm

Secondary Chamber

600L

750L

1000L

1500L

Smoke Filter Chamber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Dry Scrubber

Feed Mode

Manual

Manual

Manual

Manual

Voltage

220V

220V

220V

220V

Electricity

1.38Kw

1.69Kw

2.57Kw

4.88Kw

Diesel Oil Consumption (kg/hour)

Ave.20.4

Ave.24.2

Ave.33

Ave.44

Natural Gas Consumption (m3n/hour)

Ave.24.5

Ave.29

Ave.39.6

Ave.52.8

Infection Monitor

Yes

Yes

Yes

Yes

Temperature Protection

Yes

Yes

Yes

Yes

Oil Tank

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

200L

Nanjing Clover Medical Technology Co.,Ltd.

300L





HICLOVER Solution for Fighting COVID-19, Medical Waste Incinerator

500L

500L

 

2020-09-02



Best Feeding Door Solid Waste Incinerators HICLOVER



HICLOVER Top Feeding Door Waste Incinerators

▲Large Feeding Door
▲Better for Animal Waste Cremation
▲HICLOVER Brand Section

***Primary Combustion Chamber
***Secondary Combustion Chamber
***Smoke Filter Chamber
***Optional Wet Scrubber System(1 section or  3 sections)

Phone: +86-13813931455(whatsapp/wechat)
Website: http://www.hiclover.com/ 

Nanjing Clover Medical Technology Co.,Ltd.

Items Side Loading Door Top Loading Door
Cost Cheap High cost
Manufacture Tech. Easy A litter difficult
Safty safe safer
Incinerator Shape L/ I
Loading manual big door can be by Forklift
Land occupation small big
Ash door same with feeding door or alone alone
market share Most-CHINA/USA/INDIA Few- UK/USA
Dooring open type Manual Pry bar/Hydraulic pressure
Dooring Open size small big
Better for medical bag waste animal waste
open when burning safer, can feed waste, few smoke not safe, cannot feed waste, most smoke



parts of an incinerator
physical method of disposing hazardous chemical waste
portable incinerators types
proper ways of waste disposal in the community
questionnaire to ask about incinerators for collection of data